Simulate any condition on Earth — and beyond. Our state-of-the-art climatic chambers validate your product for the most extreme temperature, humidity, and atmospheric environments.
// Service Overview
Climatic simulation testing replicates real-world environmental conditions — temperature extremes, humidity cycles, thermal shocks, altitude, and combined atmospheres — to verify that your product will survive and perform reliably throughout its intended lifecycle.
At Arudhya Test Solutions, our NABL-accredited climatic laboratory in Hyderabad operates a comprehensive suite of environmental chambers, enabling us to cover the full spectrum of international standards from MIL-STD-810G to IEC 60068 and DO-160G.
// What We Test
Comprehensive climate testing from single-condition screening to complex multi-environment qualification sequences.
// Chamber Capabilities
Our chambers cover an unbroken temperature range from −70 °C to +180 °C — the widest climatic envelope available in Hyderabad — ensuring no test profile is out of reach.
// Test Standards
We support all major international and Indian defence standards. Filter by category below.
| Standard | Test Method / Clause | Description | Type |
|---|---|---|---|
| MIL-STD-810H | Method 501.7 | High Temperature Storage & Operation | Military |
| MIL-STD-810H | Method 502.7 | Low Temperature Storage & Operation | Military |
| MIL-STD-810H | Method 503.7 | Temperature Shock | Military |
| MIL-STD-810H | Method 500.6 | Low Pressure (Altitude) | Military |
| MIL-STD-810H | Method 507.6 | Humidity | Military |
| MIL-STD-810H | Method 509.6 | Salt Fog | Military |
| MIL-STD-810H | Method 505.6 | Solar Radiation | Military |
| IEC 60068-2-1 | Test Ab / Ae | Cold — Exposure to Low Temperature | IEC |
| IEC 60068-2-2 | Test Bb / Bc | Dry Heat | IEC |
| IEC 60068-2-3 | Test Ca | Damp Heat, Steady State | IEC |
| IEC 60068-2-14 | Test Na / Nb | Thermal Shock — Air-to-Air | IEC |
| IEC 60068-2-30 | Test Db | Damp Heat, Cyclic | IEC |
| IEC 60068-2-52 | Test Kb | Salt Mist, Cyclic | IEC |
| DO-160G | Section 4 | Temperature and Altitude | Avionics |
| DO-160G | Section 5 | Temperature Variation | Avionics |
| DO-160G | Section 6 | Humidity | Avionics |
| JSS 55555 | Part I & II | Indian Defence: Climatic Tests | Indian Def |
| ETSI EN 300 019 | Class T1–T4 | Telecom Environmental Conditions | Telecom |
| ISO 16750-4 | Climatic Loads | Automotive — Road Vehicles Environmental Conditions | Automotive |
| ASTM B117 | — | Standard Practice for Operating Salt Spray Apparatus | ASTM |
| Standard | Method | Test Description |
|---|---|---|
| MIL-STD-810H | 501.7 | High Temperature Storage & Operation |
| MIL-STD-810H | 502.7 | Low Temperature Storage & Operation |
| MIL-STD-810H | 503.7 | Temperature Shock |
| MIL-STD-810H | 500.6 | Low Pressure — Altitude |
| MIL-STD-810H | 507.6 | Humidity |
| MIL-STD-810H | 509.6 | Salt Fog |
| MIL-STD-810H | 505.6 | Solar Radiation (Sunshine) |
| MIL-STD-810H | 520.4 | Temperature, Humidity, Vibration, Altitude |
| Standard | Test Code | Description |
|---|---|---|
| IEC 60068-2-1 | Ab / Ae | Cold — Dry and Non-Condensing |
| IEC 60068-2-2 | Bb / Bc | Dry Heat — Non-Dissipating & Dissipating |
| IEC 60068-2-3 | Ca | Damp Heat, Steady State |
| IEC 60068-2-14 | Na / Nb | Thermal Shock, Air-to-Air |
| IEC 60068-2-30 | Db | Damp Heat, Cyclic (12+12 h Cycle) |
| IEC 60068-2-52 | Kb | Salt Mist, Cyclic (NaCl Solution) |
| IEC 60068-2-5 | Sa | Solar Radiation (Simulated) |
| ISO 16750-4 | — | Automotive Climate Loads |
| Standard | Section | Description |
|---|---|---|
| DO-160G | Section 4 | Temperature and Altitude — Ground Survival, Operating |
| DO-160G | Section 5 | Temperature Variation — Short-Time Thermal Shock |
| DO-160G | Section 6 | Humidity — Cyclic and Steady State |
| DO-160G | Section 24 | Icing / Freezing Rain |
| Standard | Part | Description |
|---|---|---|
| JSS 55555 | Part I | Indian Defence Environmental Requirements — Climatic |
| JSS 55555 | Part II | Mechanical & Combined Climatic |
| ETSI EN 300 019 | Class T1–T4 | Telecom Equipment — Storage, Transport, Stationary Use |
| IS / IEC 60529 | IP Codes | Degrees of Protection — Humidity & Ingress Related |
// Who We Serve
Climatic testing is critical across every sector where product reliability matters. We serve them all.
// How It Works
// Why Arudhya
We combine state-of-the-art chamber technology with deep engineering expertise and accredited credibility to deliver reliable, fast, and globally accepted test results.
All climatic test reports are NABL accredited under ISO/IEC 17025 — accepted by DGAQA, TEC, OEMs, and global regulators.
−70°C to +180°C in a single facility — no need to send hardware to multiple labs.
Compressed development cycles demand speed. We maintain best-in-class queue and report delivery times.
Watch your product's climatic test live from anywhere in the world — saving travel and time for global teams.
Our engineers help you select the right standard, profile, and failure criteria — not just run the chamber.
// FAQs
Still have questions about our climatic simulation services? Reach out — our engineers are happy to help.
// Get In Touch
Fill in the form and a qualified test engineer will contact you within 24 hours with a detailed test plan and cost estimate.
Plot No:28/2, Phase–2, IDA, Cherlapally,
Hyderabad – 500051, Telangana
+91 9505515816
env.info@arudhyatestsolutions.com
We respond to all inquiries within 4 business hours